Connecting Cisco ISDN PRI Network Modules to the Network
PRI Module LEDs
11
Connecting Cisco ISDN PRI Network Modules to the Network
Connecting CE1/PRI-U Modules to the Network
To connect a CE1/PRI-U (75-ohm) module to the network, use the appropriate cable to connect the
CE1/PRI-U port to an E1 CSU (see Figure 18). These ports are color-coded tan. The illustration shows
a CSU with BNC connectors.
Figure 18 Connecting a CE1/PRI-U Module to an E1 CSU
(DB-15-to-BNC Connectors)
PRI Module LEDs
All network modules have an enable (EN) LED. This LED indicates that the module has passed its
self-tests and is available to the router.
All PRI modules display four additional LEDs for each port. These LEDs are described in Table 4.
Channelized T1/E1 PRI Network Module with G.703 LEDs
Figure 19 and Figure 20 show channelized T1/E1 PRI network module with G.703 LEDs. See Table 5
for LED definitions.
For LEDs found on all PRI network modules, see Table 4.
LOOP
BACK
EN
FE-PRI
1FE-1CE1-B/U
LOCAL
ALARM
REMOTE
ALARM
CARRIER
DETECT
10/100BaseT
COLL
LINK
100Mbps
FDX
H7471
CE1/PRI-U
BNC connectors
E1 CSU
E1 cable for 75-ohm
unbalanced connections
with BNC connectors
at the network end
CTRLR 0
Table 4 ISDN PRI Network Module LEDs
LED Meaning
RA Local alarm at remote end of connection
LA Loss of signal, loss of frame, or unavailability because of
excessive errors
LP Loopback mode
CD Carrier received on telco link