Cisco Systems SFS 3012R Manual de instalación Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
3-11
Cisco SFS 3012R Multifabric Server Switch Hardware Installation Guide
OL-11187-01
Chapter 3 Installing and Removing Server Switch Field Replaceable Units (FRUs)
Removing a Blower Module
Removing a Blower Module
To remove a blower module, perform the following steps:
Step 1 Ground yourself using an approved ground wrist strap.
Step 2 Unfasten the captive screw.
Step 3 Pull the blower module toward you until it completely disengages from the chassis.
Step 4 Insert a replacement blower module into the empty chassis bay to ensure appropriate cooling.
Note Each blower module contains two blowers for a total of four blowers. The system can tolerate
one out of four blowers failing. When you remove a blower module, you have three minutes to
replace it with a fully-functioning blower module.
Vista de pagina 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 83 84

Comentarios a estos manuales

Sin comentarios