Cisco Systems EDFA2 Manual de operaciones Pagina 109

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 280
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 108
FINAL DRAFT - CISCO CONFIDENTIAL
6-9
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 6 ASH Commands
Configuration Commands
6.2.6 pdm busmode modify Command
Command pdm busmode modify
Syntax Description pdm busmode modify {simplex | duplex}
Modifies power bus mode to simplex (single power sourceBus A) or duplex (redundant power
sourceBus A and B).
6.2.7 pdm cfg threshold bus display Command
Command pdm cfg threshold bus display
Syntax Description pdm cfg threshold bus display
Displays the minimum and maximum allowable power bus DC voltage.
Example 6-5 pdm cfg threshold bus display Command
ash:hostname:ONS15216 EDFA2> pdm cfg threshold bus display
BUS Threshold Low = 40000(mV)
BUS Threshold High = 57000(mV)
6.2.8 pdm cfg threshold bus modify Command
Command pdm cfg threshold bus modify
Syntax Description pdm cfg threshold bus modify
Modifies minimum and maximum allowable power bus DC voltage.
Example 6-6 pdm cfg threshold bus modify Command
ash:hostname:ONS15216 EDFA2> pdm cfg threshold bus modify
BUS Threshold Low = 40000(mV)
40500
BUS Threshold High = 57000(mV)
6.2.9 gain gain display Command
Command gain gain display