Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (H.323)
OL-4008-01
Chapter 5 Parameters and Defaults
Optional Feature Parameters
Voice Configuration Menu Access Code
81
RingOnOffTime
Description
This parameter specifies the ringer cadence pattern, expressed as a triplet of integers “a,b, and c”.
a—Number of seconds to turn the ring ON.
b—Number of seconds to turn the ring OFF.
c—The ring frequency, fixed at 25.
Value Type
List of three integer values, separated by commas
Range
1-65535
Default
2, 4, 25
Recommended Values:
United States —2,4,25
Sweden — 1,5,25
Voice Configuration Menu Access Code
929
IPDialPlan
Description
This parameter allows for detection of IP-like destination address in DialPlan. Three values are valid:
0—String is dialed as is and not treated as an IP address.
1—When the Cisco ATA detects two asterisks (**), IPDialPlan takes over. The user enters the pound
(#) key to terminate the digit collection, and the interdigit timeout default is not used.
2—When IPDialPlan is set to 2, three asterisks (***) are required for IPDialPlan to take effect.
All other values are currently undefined.
Value Type
Integer
Range
0, 1 or 2