Cisco Systems ATA 188 Guía de usuario Pagina 97

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 228
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 96
5-27
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (H.323)
OL-4008-01
Chapter 5 Parameters and Defaults
Operating Parameters
Examples
The following examples are recommended values for the CallerID Method parameter:
USA=0x19e60
Sweden=0x0ff61 or 0x006aff61
Denmark=0x0fde1 or 0x033efde1
Value Type
Bitmap
Default
0x00019e60
Voice Configuration Menu Access Code
316
Polarity
Description
You can control line polarity of the Cisco ATA FXS ports when a call is connected or disconnected by
configuring the Polarity bitmap parameter as follows:
Bit 0: CALLER_CONNECT_POLARITY. Polarity to use when the Cisco ATA is the caller and the
call is connected.
0 =Use forward polarity (Default)
1 =Use reverse polarity
Bit 1: CALLER_DISCONNECT_POLARITY. Polarity to use when the Cisco ATA is the caller and
the call is disconnected.
0 =Use forward polarity (Default)
1 =Use reverse polarity
Bit 2: CALLEE_CONNECT_POLARITY. Polarity to use when the Cisco ATA is the callee and the
call is connected.
0 =Use forward polarity (Default)
1 =Use reverse polarity
Bit 3: CALLEE_DISCONNECT_POLARITY. Polarity to use when the Cisco ATA is the callee and
the call is disconnected.
0 =Use forward polarity (Default)
1 =Use reverse polarity
Note Bits 4-31 are reserved.
Value Type
Bitmap
Vista de pagina 96